Sign In | Join Free | My benadorassociates.com
China Sansion Power Electric Co., Ltd. logo
Sansion Power Electric Co., Ltd.
Building A One-stop Service Platform
Verified Supplier

1 Years

Home > AC Dielectric Test System >

150 kV 50 kVA High-Voltage Insulation Testing Equipment for Power Transformers Generators and Electrical Apparatus Featuring PD Detection and AC

Sansion Power Electric Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

150 kV 50 kVA High-Voltage Insulation Testing Equipment for Power Transformers Generators and Electrical Apparatus Featuring PD Detection and AC

Model Number : YDW

AC Test Voltage : 150 kV

Brand Name : Sansion Power

System Rating : 50 kVA

MOQ : 1

Additional Function : Partial Discharge Detection

Delivery Time : 30 Working Days

Filtering Technology : Adaptive Digital Filtering

Payment Terms : L/C,T/T

Detection Feature : High-Sensitivity Signal Capture

Packaging Details : Plywood Case

Applicable Equipment : High-Voltage Electrical Apparatus

Certification : CE/SGS/EMS/ISO 9001

Operating Frequency : Power Frequency

Place of Origin : China

Testing Method : AC Withstand Testing

Contact Now

Product Description

50kVA/150kV Power Frequency PD-Free AC Withstand Test System

A high-voltage insulation test should not only determine whether equipment withstands the required AC voltage, but also provide insight into possible insulation deterioration. This 50kVA/150kV Power Frequency PD-Free AC Withstand Test System is designed for professional testing applications where both withstand performance and partial discharge behavior need to be evaluated.

The system can be used across a broad range of high-voltage equipment, including power transformers, instrument transformers, generators, bushings, surge arresters, GIS, capacitors and switchgear. Its intelligent detection technology is designed to identify weak discharge activity with high sensitivity. At the same time, adaptive signal filtering reduces unwanted background noise, helping engineers obtain more reliable test data and reduce the possibility of missed or incorrect judgments.

Product Parameters

Item

Technical Specification

System Rating

50 kVA

AC Test Voltage

150 kV

Operating Frequency

Power Frequency

Testing Method

AC Withstand Testing

Additional Function

Partial Discharge Detection

Detection Feature

High-Sensitivity Signal Capture

Filtering Technology

Adaptive Digital Filtering

Applicable Equipment

High-Voltage Electrical Apparatus

Product Advantages
  • Two-Dimensional Insulation Evaluation: Tests withstand capability while providing information about partial discharge activity.
  • Weak Signal Recognition: Designed to detect low-level discharge signals associated with insulation abnormalities.
  • Accurate Signal Processing: Intelligent filtering improves signal quality when background interference is present.
  • Reduced Risk of Misjudgment: More reliable signal identification can assist engineers in recognizing potential insulation problems.
  • Broad Testing Range: Applicable to different types, voltage levels and capacities of high-voltage electrical equipment.
Application Scenarios
  • Transformer production and insulation inspection
  • Generator testing
  • Switchgear and GIS testing
  • High-voltage equipment acceptance testing
  • Electrical insulation research
  • Professional testing centers
FAQ

Q1: What is the difference between AC withstand testing and PD detection?
A: AC withstand testing evaluates whether insulation can withstand a specified AC voltage, while PD detection focuses on identifying weak localized discharge that may indicate insulation defects.

Q2: Can the system be used for different voltage classes of equipment?
A: Yes. The system can be applied to suitable equipment across different voltage levels and capacities according to the required test configuration.

Q3: What makes the PD detection function sensitive?
A: The system is designed to capture weak discharge signals and process them through intelligent filtering technology.

Q4: Is the equipment suitable for factory inspection?
A: Yes. It can be used for transformer and other electrical equipment production inspection, quality control and acceptance testing.

150 kV 50 kVA High-Voltage Insulation Testing Equipment for Power Transformers Generators and Electrical Apparatus Featuring PD Detection and AC

Product Tags:

150 kV high-voltage insulation tester

      

50 kVA AC dielectric test system

      

PD detection insulation testing equipment

      
Quality 150 kV 50 kVA High-Voltage Insulation Testing Equipment for Power Transformers Generators and Electrical Apparatus Featuring PD Detection and AC for sale

150 kV 50 kVA High-Voltage Insulation Testing Equipment for Power Transformers Generators and Electrical Apparatus Featuring PD Detection and AC Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Sansion Power Electric Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)