Complete GIS Testing Solution for High Voltage Withstand, Partial Discharge and Insulation Diagnostics – Advanced Gas Insulated Switchgear Test System

Model Number : SXGTU

Capacity Range : 50–2000kVA

MOQ : 1

Frequency : 50Hz/60Hz

Brand Name : Sansion Power

System Type : Resonance voltage generation

Delivery Time : 30 working days

Payment Terms : L/C,T/T

Input Voltage : 0.35–10kV

Packaging Details : Plywood Case

Certification : CE/SGS/EMS/ISO 9001

Cooling method : Air cooling

Place of Origin : China

Power consumption : 500W

Contact Now

Product Description

The Complete GIS Testing Solution is positioned as a comprehensive platform for customers who need more than a single high-voltage test instrument.

It combines GIS high-voltage withstand testing, partial discharge measurement and insulation diagnostics into a configurable testing solution for GIS manufacturers, utilities, laboratories and commissioning companies.

The concept follows the current direction of GIS testing, where withstand testing and PD measurement are increasingly considered complementary rather than completely independent tests.

Complete Testing Functions
High Voltage Tests
  • AC withstand voltage test
  • Power-frequency withstand test
  • Variable-frequency AC test
  • Resonance high-voltage test
  • GIS insulation test
Partial Discharge Tests
  • Partial discharge detection
  • PDIV measurement
  • PDEV measurement
  • Apparent charge measurement
  • PRPD analysis
  • UHF PD detection
  • Noise analysis
  • PD trend analysis
Project Applications
  • GIS factory acceptance testing
  • GIS commissioning
  • GIS installation testing
  • GIS preventive maintenance
  • GIL testing
  • High-voltage laboratory testing
  • Research and development
  • Insulation diagnostic testing
Why Choose a Complete GIS Test Solution?

More than a withstand test

The customer receives information about both dielectric withstand capability and PD activity.

More efficient testing workflow

The high-voltage source, measurement system and control system can be designed as one integrated solution.

Flexible for different GIS projects

Voltage level, test capacity, PD measurement method and control architecture can be customized.

Suitable for international projects

The system can be engineered according to the applicable project standards and customer specifications.

FAQ
What standards are commonly associated with GIS high-voltage and PD testing?

Depending on the test being performed, customers may encounter standards such as IEC 62271-203, IEC 60060-1 and IEC 60270. The exact standard and test procedure should be confirmed according to the project specification and GIS application.

What is the difference between IEC 60270 PD measurement and UHF GIS PD detection?

IEC 60270 is associated with conventional apparent-charge measurement using a suitable measuring circuit, while UHF detection uses high-frequency electromagnetic signals generated by PD inside GIS. The two approaches have different measurement principles and application characteristics.

Can one system support both methods?

A customized GIS testing platform can be designed to support multiple PD measurement methods where required.

How do I choose the right GIS test system?

The most important information includes:

  • GIS rated voltage
  • Required test voltage
  • GIS capacitance
  • Test frequency
  • Required test current
  • PD measurement method
  • Required PD sensitivity
  • GIS configuration
  • Indoor or outdoor application
  • Factory or field testing
  • Applicable standards
Can the system be customized for 110kV, 220kV, 500kV or higher GIS?

Yes. High-voltage GIS testing systems are normally engineered according to the customer's actual GIS parameters rather than selected only by voltage class. For example, commercially available systems cover GIS testing at different voltage levels, while higher-voltage applications require corresponding changes to the test circuit, insulation design, capacity and site configuration.


Product Tags:

GIS high voltage withstand test system

      

gas insulated switchgear partial discharge tester

      

AC high voltage insulation diagnostics equipment

      
Quality Complete GIS Testing Solution for High Voltage Withstand, Partial Discharge and Insulation Diagnostics – Advanced Gas Insulated Switchgear Test System for sale

Complete GIS Testing Solution for High Voltage Withstand, Partial Discharge and Insulation Diagnostics – Advanced Gas Insulated Switchgear Test System Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Sansion Power Electric Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)